<Parameter>
<ParameterFamily>media</ParameterFamily>
<LongName>
debris_option
</LongName>
<Name>
dopt
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Thermal</TextApplies></ListItem>
<ListItem><TextApplies>Green</TextApplies></ListItem>
<ListItem><TextApplies>HRX</TextApplies></ListItem>
<ListItem><TextApplies>Platesetter_3244</TextApplies></ListItem>
<ListItem><TextApplies>Platesetter_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
<ListItem><TextApplies>ThermoFlex</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800_Auto</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800_Proofing</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This parameter defines the debris removal method(s) used for the associated media.
Depending on this parameter the whisker jet, POC, PACC or PACC Flexo may be used
during imaging.  The whisker jet can be combined with each of the other debris options
and the valid logical combinations result in these possibilities for the dopt parameter:
</text></DescriptionText>
<DescriptionText><text>
Entry ------ Thickness
</text></DescriptionText>
<DescriptionText><UnnumberedList>
<ListItem><Text> 0 ....... No debris removal</Text></ListItem>
<ListItem><Text> 1 ....... Whisker Jet only</Text></ListItem>
<ListItem><Text> 2 ....... POC only</Text></ListItem>
<ListItem><Text> 3 ....... POC + Whisker Jet</Text></ListItem>
<ListItem><Text> 4 ....... PACC</Text></ListItem>
<ListItem><Text> 5 ....... PACC + Whisker Jet</Text></ListItem>
<ListItem><Text> 6 ....... **Invalid**</Text></ListItem>
<ListItem><Text> 7 ....... **Invalid**</Text></ListItem>
<ListItem><Text> 8 ....... Flexo PACC</Text></ListItem>
<ListItem><Text> 9 ....... Flexo PACC + Whisker Jet</Text></ListItem>
</UnnumberedList></DescriptionText>
<DescriptionText><text>
All PACC configurations require a UDRC-L cabinet be setup with the device.
</text></DescriptionText>
<DescriptionText><text>
Note:
</text></DescriptionText>
<DescriptionText><UnnumberedList>
<ListItem><Text> POC = Particulate Only Cabinet</Text></ListItem>
<ListItem><Text> PACC = Particulate and Chemical Cabinet</Text></ListItem>
</UnnumberedList></DescriptionText>
</Description>
<Type>
byte
</Type>
<Default>
<UnnumberedList>
<li>0</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 5 (max of 9 on ThermoFlex devices)</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:11 2008 PST
</Updated>
<Links>
</Links>
</Parameter>